C O N T R O L E L E M E N T S
C O N T R O L E L E M E N T S
C O N T R O L E L E M E N T S
> > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > >
> > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > > >
88
Manual SDs-01 E 3.2.2003 18:26 Uhr Seite 6
3 IN WCLK OUT
The left hand side connector (IN) receives a Word Clock or so-called »Super
Clock« signal as master clock reference for the SRCs. The right hand side
connector (OUT) transmits an Ultra low-jitter Word Clock signal based on
the internal clock basis or the selected external clock reference signal. The
impedances of both connectors are 75 (BNC connectors, female).
4 ADAT
TM
IN
These two optical inputs receive digital audio multichannel signals incom-
pliance with the Alesis ADAT
TM
format. Input »A« alone accepts ADAT
TM
signals up to 50.0kHz. For receiving ADAT
TM
signals with higher clock rates
up to 192.0kHz, both inputs »A« and »B« are used simultaneously (Toslink
TM
connector, EIAJ standard).
5 S/PDIF IN/OUT
These interfaces function as receiver and transmitter for S/PDIF digital audio
signals in compliance with the IEC 60958 standard. Their function depends
on the selected operation mode, which is displayed on the front panel. The
impedance of all connectors is 75 (Cinch connectors, female).
6 ADAT
TM
OUT
These two optical outputs transmit digital audio multichannel signals
incompliance with the Alesis ADAT
TM
format. Output »A« alone transmits
ADAT
TM
signals up to 50.0kHz. For transfering ADAT
TM
signals with higher
clock rates up to 192.0kHz, both outputs »A« and »B« are used simultane-
ously (Toslink
TM
connector, EIAJ standard).
7 MAINS IN, Power Switch + Power Inlet
This is the main switch for switching the device on and off. Be sure to
make all connections (especially the supplied power cable) properly before
turning on the switch. Heed the SAFETY INSTRUCTIONS at the beginning of
this manual.
Connect the supplied power cable here. Make sure that the power switch
is turned off before connecting the power cable to this inlet and to the
power outlet. Line voltages within the range of 90…260V with a frequen-
cies between 47...440Hz can be applied. The internal power supply will
automatically make all necessary adjustments.